Frequently Asked Questions | EMF Detection UK (Substation Health Risks)
Electricity pylons and EMF field

Frequently Asked Questions

Straight answers on EMF exposure, guidelines and what our own survey archive actually shows - backed by real readings, not generic explainers.

Quick answers

The questions we're asked most.

Short, direct answers. For the bigger questions, see the deep dives below, each one backed by a real result from our published case studies.

Q

What does 400nT mean, and where does the number come from?

400 nanotesla (nT), or 0.4 microtesla, is the precautionary household guideline that came out of the SAGE process (Stakeholder Advisory Group on ELF EMFs), initiated by the National Grid and later led by the Department of Health, jointly funded with the charity Children with Leukaemia. SAGE's first interim assessment in 2007 recommended keeping household exposure below this level as a precaution linked to childhood leukaemia research. A reading above 400 nT doesn't mean harm is certain, but SAGE treats it as a level worth avoiding where reasonably practicable.

Q

What's the difference between SAGE, ICNIRP and CEMFAW?

SAGE is a UK precautionary guideline for domestic exposure, set at 400 nT. ICNIRP 2010 is the international guideline power companies reference, with a public exposure action level of 100,000 nT (100 microtesla), 250 times higher than SAGE. CEMFAW (the Control of Electromagnetic Fields at Work Regulations 2016) is a separate, legally binding UK regulation covering occupational exposure. A reading can fail SAGE's precautionary threshold while comfortably passing ICNIRP, which is exactly what happened in our Toton and Borehamwood case studies.

Q

What's a "safe" EMF reading for a home?

There's no single legal safety limit for UK homes, only guidelines. SAGE's 400 nT is the most cautious benchmark commonly used; ICNIRP's 100,000 nT is the internationally referenced ceiling. Most properties in our published archive read well under 100 nT, so anything meaningfully below 400 nT is typical for a UK home. Readings above it are unusual but not automatically dangerous, which is why we report the actual number against both guidelines rather than a simple pass or fail.

Q

Do EMF readings change throughout the day?

Yes. Magnetic flux from the electricity network fluctuates continuously depending on local demand, and tends to follow a repeating pattern over roughly a 7-day cycle rather than staying constant. A survey is a real-time snapshot taken under the conditions on the day, which is why our reports record the exact date, time and atmospheric conditions of the assessment alongside the readings.

Q

Is CEMFAW compliance a legal requirement for my business?

Yes, if you're a UK employer. The Control of Electromagnetic Fields at Work Regulations 2016 place a legal duty on all UK employers to assess and manage staff exposure to electromagnetic fields, separate from any voluntary domestic guideline. This is most relevant for manufacturing, healthcare, education and utilities businesses operating near electrical infrastructure. We carry out fully CEMFAW compliant workplace assessments with the documentation needed to satisfy that legal duty.

Q

How long does an EMF survey take, and what do I get?

On-site time is typically around an hour, with measurements taken at multiple points in each room plus garden and boundary areas. You receive a full written report within 2-3 business days, including frequency charts for every location measured, a comparison against the relevant guidelines, and a plain-English conclusion. Raw data is kept confidential and destroyed seven days after delivery unless you ask us in writing to retain it.

Q

What equipment do you use, and how does it work?

Our engineers use calibrated data-logging equipment that records magnetic field strength continuously across three directional axes (X, Y and Z) at each measurement point, rather than taking a single static reading. That logged data is then processed through dedicated software to calculate the combined "true RMS" (root-mean-squared) field strength and to generate the frequency charts included in every report. We don't publish the specific make and model of our equipment, but every reading is backed by an electronic, time-stamped data file, not a single spot-check with a handheld meter.

Q

Can EMF levels be reduced or shielded?

In some cases, yes, particularly for radio-frequency (RF) sources like a neighbour's Wi-Fi router, where shielding can reduce exposure through a shared wall, as recommended in our Derby and Ealing case studies. For low-frequency (ELF) magnetic fields from substations or cabling, options are more limited and usually relate to distance, cable routing or building layout rather than shielding products. We report what we find and what's realistically achievable, not a fix that isn't warranted.

Answered with real data

The bigger questions, with real readings attached.

These four come up the most, and deserve more than a generic paragraph. Each one draws on a specific result from our published case studies, not a hypothetical example.

Substations

Is it safe to live near an electricity substation?

There's no single answer, because it depends on the specific property, not just the distance to the substation. Our own archive shows the range: Muswell Hill recorded 332.14 nT on the front path, 83% of the 400 nT SAGE threshold, and still passed comfortably. Toton, by contrast, is the one result in our published case studies that exceeds a guideline: every room read above 400 nT, with the garden at 578.44 nT, the same survey passed against ICNIRP, the guideline actually referenced by power companies, at a fraction of its 100,000 nT action level. Underground cable routing, substation load and building construction all matter more than raw distance, which is exactly why a calibrated, independent reading is the only way to know for a specific property.

See the Toton and Muswell Hill results →
Property and planning

Do pylons or substations affect house prices?

It's a real concern for buyers, sellers, lenders and solicitors, which is why an EMF report is often requested before exchange. We're not valuers, so we won't quote a percentage discount, but concern about EMF exposure has been raised as a formal planning objection in real cases, including submissions that cited our own published research to the Planning Inspectorate, Sheffield City Council and Bickleigh Parish Council. Whatever the property, an independent report that gives a definitive reading, rather than leaving the question open, is what solicitors and lenders actually rely on at the point of sale.

See where our research has been cited →
Guidelines

SAGE vs ICNIRP: why do two guidelines give such different answers?

They're measuring against different goals, not disagreeing about the physics. SAGE is a precautionary household guideline, set at 400 nT specifically with childhood leukaemia research in mind, developed jointly by the Department of Health, the electricity industry and the charity Children with Leukaemia. ICNIRP 2010 is the guideline power companies reference for public exposure, set at 100,000 nT, a limit intended to prevent known short-term biological effects, not a precautionary childhood-health benchmark. Neither is wrong; they answer different questions. We report every result against both, so you can see which standard a reading is being judged against rather than a single unexplained pass or fail.

See every result against both guidelines →
EMF vs RF

What's the difference between EMF and RF exposure?

EMF in the sense most of our surveys measure is extremely low frequency (ELF) magnetic flux from the mains electricity network, substations, cabling and overhead lines, typically around 50 Hz. RF (radio-frequency) exposure is a different part of the spectrum entirely, covering Wi-Fi, mobile networks and similar wireless sources. Our Derby case study is a good example: the property passed comfortably on ELF, but 815 microwatts per square metre of RF exposure in the living room was traced to a neighbour's Wi-Fi router through a shared wall. Our Ealing case study found a similar pattern with mobile phone antennae. The two are assessed against different guidelines entirely, which is why we test for both rather than assuming one covers the other.

See the Derby and Ealing results →

Still have a question?

If your situation isn't covered above, get in touch directly, we're happy to talk it through before you book anything.